DISTRIBUTION MOTOR OPERATOR

UAD

Decoration

The UAD motor operator is used to automate underground SF6 and vacuum switches. The motor operator opens and closes the switch with an operating time of 12 seconds with a torque of 3000 in-lbs. Other operating times and torques are available upon request.

UAD motor assemblies connect directly to an underground switch’s manual operation location with mounting kit and linkages furnished by C/P. The motor assembly is connected by cable to the control enclosure with fully submersible motor and motor connections to survive flooded vault occurrences.

UAD Motor Operator Features

Decoration
  1. NEMA 3R powder coated aluminum enclosure
  2. Fully gasketed enclosure
  3. Local operational controls
  4. Battery
  5. Control electronics
  6. Stainless steel door hinge, stop, and handle
  7. Provisions for RTU and radio
  8. Removable access plate

UAD Motor Callout

Decoration

9. Cable to controller

10. Locking disc

11. Position arrow

12. Fully sealed stainless steel enclosure

Power Train

Decoration

The UAD motor operator is driven by a 24V permanent magnet motor. A patented dynamic braking circuit is used to provide an extremely precise stopping point in both the open and closed positions. The braking action is initiated by a programmable front panel at the ends of travel. The UAD motor operator utilizes a gear driven mechanism that has limits of travel set at the front panel rather than limit switches inside the motor.

Battery

Decoration

The battery used in the motor operator is an SLA (sealed lead-acid) type. The battery typically has a 4–5 year life, depending upon duty and environment. In regions with sustained high temperatures, the life of the battery may be extended through use of the Cleaveland/Price battery cooler accessory that provides an optimal constant temperature environment.It has a pressure relief valve that only opens during excessive gas buildup. Gasses are vented via a hose to the outside of the enclosure, preventing the buildup of corrosive and explosive gasses within the enclosure. 

Battery and Charging

Decoration

All motor operators utilize a 12V 33AH battery that is charged by a transformer. The battery charger is temperature compensated so that the battery always receives the proper charging voltage. The battery can operate a switch over 100 times on a full charge and can keep the UAD powered for up to 72 hours after loss of charging power. The battery charger provides several status points that are reported to the supervisor system that alert the utility of battery condition. That battery condition is provided in real time with the battery automatically checked every five minutes to ensure that you have an accurate date battery health indicator.

Operation

Decoration

Operations can be initiated locally, remotely, or manually. Local operations are performed via the front panel, remote operations occur via communication device and remote terminal unit (RTU) contact closure, and manual operations are completed with a manual handle.

Motor operators run the motor from the 120V feed as the primary power source and uses the 12V battery as a backup. Because the motor operator uses AC as its primary power source, the motor operator will run if AC is present even if the battery is weak. AC and battery power are supplied to the motor concurrently. This means the motor operator will complete an operation without hesitation, even if AC is lost during the operation (such as having the distribution transformer on the load side of the switch).

The motor operator incorporates a stall timer that automatically terminates motor operation after a predefined time interval. If the motor operator stalls due to switch icing or a mechanical obstruction, the timer ends the operation before prolonged stall current can cause the DC fuse to open. This feature helps prevent the unit from becoming inoperable and reduces the need for field service associated with fuse replacement.

Enclosure and Wiring

Decoration

The motor operator enclosure offers sufficient room to house most RTUs and radios with all components accessible through the front door. It is designed for mounting on a concrete pad, allowing cables to enter through conduit embedded in the pad and remain fully protected as they route into the underground vault housing the switchgear. The enclosure is powder coated white to provide a surface that reflects the heating rays of the sun thereby reducing heat buildup within the enclosure, increasing the lifetime of the battery.

Cleaveland Price can factory install radios, RTU, sensors, relays, and any other specialty device. When installed at the C/P factory, our production team will verify the functionality of each device, ensuring that the motor operator requires minimal field installation time.

Alternate Configuration

Decoration

The UAD is designed for operating a single, below-ground switch with an above ground motor operator. Cleaveland/Price offers variants of this design for specific applications:

  • RT-UAD – For switches that require a faster operation. The RT-UAD motor can operate 90° in 0.4 seconds.
  • UAD-V – For urban applications where above ground mounting of the motor operator is not feasible. The UAD-V is submersible for mounting in the vault with the switchgear.
  • UAD-M – For operating more than one switch in a single, above ground enclosure.

By The Numbers (Switch Type)

Decoration
Battery Charger VoltageOutput Torque (lbs)Operating Time (90°)Switch TypeSchematic DiagramWiring DiagramOutline Number
120VAC3,0004 secondsSF6C128B996C132B555CB32AA01G001
120VAC3,0004 secondsVacuumC128B996C132B503CB32AA05G001

Switch Kit Information

Decoration
Switch ManufacturerSwitch Type / FeaturesMounting Kit
Elastimold MVIMVI-3C132B004G002
Elastimold MVSMVS-3C132B004G001
G&WWith pressure switchC132B005G001
G&WWithout pressure switchC132B005G002
Canada Power ProductsLever driveC132B021G001
S&CVistaC132B008G001
PowellDirect DriveC132A049G001

Motor Operators and Controllers

Superior Reliability Through Design

Decoration

In everyday switching operations or emergency situations, a motor operator must operate when needed. Cleaveland/Price Inc. has been manufacturing motor operators since the 1990s and has developed field proven and reliable devices that give you the confidence that the motor will operate the switch when called upon. With thousands of installations throughout North America, Cleaveland/Price motor operators and controllers have demonstrated their dependability in a wide variety of environments and applications.

Substation

Distribution

Transmission

Industrial Control Enclosures